The Ecler SAMI-612 is a 6-Channel 19" Analogue Stereo Installation Rack Mixer featuring six MIC/LINE stereo inputs, per-channel 3-band tone control, front panel direct microphone input, talkover priority and a MUTE remote control port.
Comprehensive and professional 1RU mixing solution for retail, education, corporate, hospitality and sports and wellness installations.
The Ecler SAMI-612 steps up the SAMI series with six MIC/LINE stereo inputs — providing greater input capacity for more complex installation audio systems where multiple microphone and line-level sources need to be managed from a single, rack-mountable mixing unit.
Designed specifically for professional fixed audio installations across retail stores, educational facilities, corporate offices, hospitality venues and sports and wellness spaces, the SAMI-612 combines comprehensive mixing capability with the practical installation features that professional integrators and installers require — all in a compact 1RU 19" rack format. A dedicated stereo MIX input also allows a second mixer to be connected directly to the mixing bus, enabling the number of inputs to be expanded further for larger or more complex system designs.
Per-Channel 3-Band Tone Control
One of the standout features of the SAMI-612 over the smaller SAMI-402 is its per-channel 3-band tone control section — accessible via screwdriver on each individual input channel. Bass (100Hz ±15dB), Mid (2kHz ±15dB) and Treble (10kHz ±15dB) adjustment is available independently for every channel, providing a level of tonal control that is fundamental to achieving a well-balanced and professional microphone mix in a fixed installation environment. Where a single global EQ can only compensate for general tonal imbalances, per-channel EQ allows each individual microphone or source to be tailored precisely — accounting for differences in microphone type, placement and the characteristics of individual voices.
High-Quality Audio Performance
The SAMI-612 maintains the same high audio quality standards as the rest of the SAMI series. Line inputs achieve a frequency response of 10Hz to 50kHz (-1dB), THD+Noise less than 0.005% and SNR greater than 100dB. Balanced MIC inputs achieve a frequency response of 10Hz to 30kHz (-1dB) and SNR greater than 85dB with CMRR greater than 60dB at 1kHz. All MIC inputs support +18V phantom power, and microphone sensitivity is adjustable via rear panel controls for precise level matching across all channels.
Front Panel Direct Mic Input, Talkover & Safety Integration
Channel 1 of the SAMI-612 features a dedicated front panel jack connector for direct microphone connection — a practical feature for installations where quick and convenient front-panel microphone access is required without routing cables to the rear of the rack. Channel 1 also carries the talkover (priority) function with internally adjustable release time, automatically ducking the mix output by -30dB when the channel 1 microphone is active. A MUTE remote control input — triggered by external dry contact closure — enables integration with fire detection systems and emergency alert devices for automatic audio muting. A VU-meter monitors the mix signal level, and the main output is switchable between stereo and mono operation.
Ecler SAMI-612 Key Features:
- 6-Channel 19" 1RU Installation Mixer: 6 x MIC/LINE stereo inputs plus a dedicated stereo MIX input for direct mixer-to-mixer bus expansion.
- Per-Channel 3-Band Tone Control: Independent Bass, Mid and Treble EQ on every input channel for precise tonal shaping of each individual source.
- +18V Phantom Power: Available on all MIC inputs for condenser microphone compatibility.
- Front Panel Direct Microphone Input: Channel 1 jack connector for quick, convenient front-panel microphone access.
- Talkover (Priority) Function: Assigned to channel 1 with internally adjustable release time and -30dB ducking effect for clear microphone priority over the mix.
- Adjustable MIC Sensitivity: Rear panel microphone sensitivity adjustment (±15dB) per channel for precise level matching.
- Main Mix Output: Switchable stereo/mono output via 3-pin Euroblock.
- AUX/REC Output: Additional stereo RCA output with internally selectable level (0dB or +6dB) for recording or zone feed applications.
- Mixing Bus Expansion: Direct stereo MIX input allows a second mixer to be connected for increased input capacity.
- MUTE Remote Control Input: External dry contact closure for integration with fire detection and other safety systems.
- VU-Meter: Mix signal level monitoring via front panel LED VU-meter.
- Passive Cooling: Silent operation for noise-sensitive installation environments.
- Universal Mains Input: 100–240V AC, 50–60Hz via external PSU.
-
Supplied with PSU, Euroblocks, Rubber Feet & Mini Jumpers: Ready for immediate installation out of the box.
SPECS & DOWNLOADS
Ecler SAMI-612 Specifications:
Download the PDF Data Sheet HERE >
Inputs
- Input Channels: 6 x MIC/LINE stereo, 1 x stereo MIX LINE
- MIC Connection: 3-pin Euroblock (balanced)
- LINE/MIX Connection: RCA
- Front Panel Input: Channel 1 jack (direct microphone connection)
- Input Sensitivity: LINE 2–5: 0dB / LINE 6: 0dB or -6dB (internally selectable) / MIC 1–5 BAL: -35dB
- Input Sensitivity Adjust: MIC/LINE ±15dB
- Input Impedance: LINE 1–6: 50kΩ / MIX LINE: 10kΩ / MIC 1–6 BAL: >1kΩ
- Phantom Power: +18VDC (all MIC inputs)
- CMRR: MIC > 60dB at 1kHz
Outputs
- Main Output: 1 x stereo/2 x mono (3-pin Euroblock), 0dB nominal, 600Ω
- AUX/REC Output: 1 x stereo RCA, 0dB or +6dB (internally selectable), 10kΩ
Signal
- Frequency Response: LINE: 10Hz–50kHz (-1dB) / MIC BAL: 10Hz–30kHz (-1dB)
- THD+Noise: LINE < 0.005% / MIC BAL < 0.04%
- SNR: LINE > 100dB / MIC BAL > 85dB
Control
- Tone Control: 3-band per channel — Bass 100Hz ±15dB / Mid 2kHz ±15dB / Treble 10kHz ±15dB
- Talkover: Channel 1, internally adjustable release time, -30dB ducking effect
- MUTE Port: NO/NC dry contact closure
- Indicators: Power LED, MUTE LED, VU-meter level LEDs
Electrical
- Power Supply: ±17.5VDC external PSU (included)
- Mains Input: 100–240V AC, 50–60Hz
- Power Consumption: 14.5VA / 6.8W
- Cooling: Passive
Physical
- Installation Format: 19" rack, 1RU
- Dimensions (W x H x D): 482.5 x 44 x 153.7mm
- Weight: 1.9kg
- Operating Temperature: -10°C to +40°C
- Operating Humidity: < 85% RH
- Included Accessories: ±17.5VDC multi-plug PSU, Euroblocks, rubber feet, mini jumpers

View our shipping and delivery information below. All prices include VAT.
Important notice for non-UK orders: Any order being shipping outside of the UK will incur an import tax. See below for more information.
Cut-off Times
Orders must be placed before 3:30pm to guarantee same-day dispatch. Any orders placed after this time are not guaranteed to be shipped the same day, and are more likely to be shipped the next working day.
To guarantee Saturday Delivery, orders must ideally be placed before 2pm.
We operate during office hours, Mon-Fri, 9am - 5pm, and are closed during the weekend.
Orders placed over the weekend or Friday after cut-off will be processed and shipped the following Monday (or Tuesday during bank holidays).
Mainland UK Delivery Charges
Note: Next-day services are classed as working days (Mon-Fri) and do not include weekends. Please choose Saturday delivery if you require the item over the weekend.
Please also note orders with a high number of boxes may be subject to an additional charge.
All delivery options will be available at the checkout stage. Please ensure you add a mobile number to your order for tracking information.
Offshore & International

We ship to Scottish Highlands, Islands, Ireland and the EU. Please see the table below for base prices. Please note that these prices are subject to change based on the number of boxes.
The following postcodes fall under 'Highlands & Islands', and are subject to the above rates/lead time.
- Scottish Highlands: FK17-21, IV1-39, IV52-54, IV63, KW1-14, PA21-40 (excluding PA38), PH19-26, PH30-41, PH49-50
- Scottish Islands: HS1-9, IV40-51, IV55-56, KA27-28, KW15-17, PA20, PA38, PA41-49, PA60-78, PH42-44, ZE1-3
If a UK Mainland next-day service is selected at checkout, please be aware that it won't be sent on that service.
If you require a next-day service to Northern Ireland and the highlands, get in touch so we can assist further.
EU Import Tax
Any goods shipped outside of the UK, over a certain value, will incur an import tax. The cost and rate will depend on the country and the order value.
This is a legal requirement and MUST be paid prior to delivery in order to receive your goods. You will be contacted by the courier once the order is dispatched to pay the fee.
Failure to pay import tax when applicable will result in the order being shipped back to Audio Volt. Any returned goods sent back to us due to non-payment of import tax are NOT ELIGIBLE for a refund on the shipping charge.
You can obtain an import duty estimate here.
Delivery Notes
On delivery, you must inspect the goods carefully for damage as Audio Volt is unable to accept responsibility for damage in transit, shortage of delivery or loss of products unless the customer advises Audio Volt of such within three working days from the date of delivery.
60 Day Returns Policy
We ask that you follow these guidelines to help us process your return as quickly and efficiently as possible:
- Please keep your order reference to hand. This confirms your original order and gives us the necessary details to authorise the product's return.
- Contact our Customer Services Team on 02476 369890 (or email info@audiovolt.co.uk). We will then send you an RMA number and a returns form, which needs to be completed and sent back with the returned item(s).
- If the order has been unpacked, re-package it to ensure that it is being returned in its original condition. Please make sure all items relating to the product are returned, including manuals and cables.
- When returning an item, please obtain a proof of postage receipt from the courier.
Returned items must be mailed within 10 days of when the RMA number has been issued. Items received with a post date 30 days after your requested return will NOT be eligible for refund.
Please note: our returns policy is quite straightforward, but there are a number of conditions that we ask our customers to comply with before applying:
- It is your responsibility to request a return. If you don't tell us you want to make a return, we don't know. Once you do tell us, we will do everything we can to action it.
- If you have not requested a return within 60 days of receiving an order, we will assume that you are intending to keep it, and we will not authorise a return.
- We always refund the payment according to how the original purchase was made and aim to do so within 72 hours of the return being received by us.
- Returned goods are liable for a restocking fee of 15% towards handling and repackaging if the order is not returned in its original, unopened packaging. This charge will be subject to our inspection of the returned goods.
- Delivery charges will not be refunded unless the delivered goods are faulty.
- Replacement products are dispatched immediately after the returned goods have been received and accepted by Audio Volt.
- Items that develop a fault within 30 days of delivery are eligible for a replacement or a refund. Delivery costs are also reimbursed for faulty items. Please contact our Customer Services Team on 02476 369890 if you believe your item has developed a fault.
Finally, please remember that notifying us of your intention to apply for a return, saving the delivery paperwork and keeping the order in its original packaging will help both you and Audio Volt to process the return quickly.
Any Questions?
If you have any questions about our returns policy, please telephone us on 02476 369890 or email us at info@audiovolt.co.uk.
We operate during office hours, Mon-Fri, 9am - 5pm, and are closed during the weekend.